580-00
Restraint joint for screw socket connection

This restraint joint is used in the field of underground pipeline construction to establish restraint connections between DCI, PE or PVC pipes and screw sockets.

PLEASE NOTE: In the area of sealing and gripping the pipe to be connected has to be clean, free from grease, soap and bitumen layers or loose layers. The grip rings shall be protected from dirt, exposure to UV light and mechanical damage. Grip rings must not be put on cement coatings.

Material: Half shells/clamping jaw: GJS-400, Hawle epoxy powder coated

Hinged axle: stainless steel

Grip ring depending on kind of pipe:
DCI pipe: PA with gripping segments
Max. operating Pressure: Sewage water: 16 bar
Potable water: 16 bar
Medium Water / Sewage

This restraint joint is used in the field of underground pipeline construction to establish restraint connections between DCI, PE or PVC pipes and screw sockets.

PLEASE NOTE: In the area of sealing and gripping the pipe to be connected has to be clean, free from grease, soap and bitumen layers or loose layers. The grip rings shall be protected from dirt, exposure to UV light and mechanical damage. Grip rings must not be put on cement coatings.