- 1)
- Material: steel, welded structure
540-00
EU-fitting (flanged socket) - BAIO® system
Material: |
GJS-400, Hawle epoxy powder coated Gasket: EPDM acc. to KTW-BWGL |
---|---|
Max. operating Pressure: | See table |
Medium | Water / Gas / Sewage |
The flanged socket serves as transition fitting from flange systems to the BAIO® system.
With one flange, and with one BAIO® double function socket for the restraint connection with BAIO® spigot ends and for connecting DCI, steel, PE and PVC pipes.
Flange dimensions: acc. to EN 1092-2
Gaskets for the medium water:
DCI pipes: BLD® gasket
PE/PVC pipes: GKS gasket
Gaskets for the medium gas:
Gas-resistant DCI pipe gasket or gas-resistant GKS gasket (PVC pipe, 5 bar) required
Order Nr.
|
*) |
DN1 |
DN2 |
Operating pressure max. |
PN |
L |
B |
H |
Medium | Weight | Specification | Basket |
---|---|---|---|---|---|---|---|---|---|---|---|---|
5400800000
|
80 | 80 | 16 bar | 10|16 | 170 mm | 200 mm | 200 mm | 7,70 kg | ||||
5401000000
|
100 | 100 | 16 bar | 10|16 | 175 mm | 220 mm | 220 mm | 9,10 kg | ||||
5401250000
|
125 | 125 | 16 bar | 10|16 | 180 mm | 250 mm | 250 mm | 11,60 kg | ||||
5401500000
|
150 | 150 | 16 bar | 10|16 | 180 mm | 285 mm | 285 mm | 13,20 kg | ||||
5402000000
|
200 | 200 | 10 bar | 10 | 185 mm | 340 mm | 340 mm | 19,10 kg | ||||
5402006000
|
200 | 200 | 16 bar | 16 | 185 mm | 340 mm | 340 mm | 19,10 kg | ||||
5402500000
|
250 | 250 | 10 bar | 10 | 221 mm | 395 mm | 395 mm | 25,00 kg | ||||
5402506000
|
250 | 250 | 16 bar | 16 | 221 mm | 405 mm | 405 mm | 25,50 kg | ||||
5403000000
|
300 | 300 | 10 bar | 10 | 251 mm | 445 mm | 445 mm | 36,50 kg | ||||
5403006000
|
300 | 300 | 16 bar | 16 | 251 mm | 460 mm | 460 mm | 37,50 kg | ||||
5408080100
|
1) | 80 | 100 | 16 bar | 10/16 | 180 mm | 220 mm | 220 mm | 10,20 kg | |||
5408100150
|
100 | 150 | 16 bar | 10/16 | 175 mm | 285 mm | 285 mm | 11,50 kg | ||||
5408150200
|
1) | 150 | 200 | 10 bar | 10 | 160 mm | 340 mm | 340 mm | 17,32 kg |
-
Factory preinstalled BAIO® lip gasket (BLD®) for DCI pipes
-
When PE or PVC pipes are connected, a surcharge for GKS gaskets must be considered.
-
Product numbers for gas on request.
-
When connecting PE pipes a support liner must be used.
Operating instructions
|
---|
Operating and maintenance instructions - BAIO® - System |
Article Nr.
|
Product description |
---|---|
440-00 | Combi-IV gate valve with flanges |
445-00 | Combi-III gate valve with flanges |
452-00 | PE fusion end incl. lock ring - BAIO® system |
452-01 | Steel fusion end incl. lock ring - BAIO® system |
528-00 | Hawle-Stop restraint joint for DCI, PE and PVC pipes - BAIO® system |
529-04 | Dirt gasket for sockets - BAIO® system |
529-05 | Twist lock device for BAIO® spigot end - socket connections |