- 1)
- Use extension spindles 910-00, 960-00 or 962-00
- 2)
- Use extension spindles 900-00, 950-00 or 952-00
405-00
Gate valve "E2" and "E3" with PE fusion ends


Material: |
Body: GJS-400, Hawle epoxy powder coated Spindle: stainless steel Wedge nut: brass Wedge: GJS-400, EPDM inside and outside acc. to KTW-BWGL for water Gaskets: EPDM acc. to KTW-BWGL for water PE end: PE 100 incl. support liner of stainless steel |
---|---|
Max. operating Pressure: | See table |
Medium | Water |
Shut-off valve with two PE fusion ends for welding into PE pipelines via resistance welding or butt welding. The PE fusion ends are factory-locked against rotation.
It can be operated via handwheel, extension spindle or motorised rotary actuators (from DN 50 on request).
Hawle E3 gate valves for potable water are suitable for commercially available heat transfer fluids with antifreeze additives and, as a rule, corrosion inhibitors.
Order Nr.
|
*) |
DN |
Description |
Operating pressure max. |
d |
Type / Outlet |
L |
L1 |
B |
H |
Medium | Weight | Specification | Basket |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4050321000
|
1) | 25 | Potable water SDR 11: 16 bar | 32 mm | Typ E2 | 520 mm | 160 mm | 2,9 mm | 160 mm | 3,15 kg | ||||
4050401000
|
1) | 32 | Potable water SDR 11: 16 bar | 40 mm | Typ E2 | 555 mm | 160 mm | 3,7 mm | 190 mm | 5,00 kg | ||||
4050501000
|
1) | 40 | Potable water SDR 11: 16 bar | 50 mm | Typ E2 | 575 mm | 165 mm | 4,6 mm | 195 mm | 5,90 kg | ||||
4050633006
|
2) | 50 | Potable water SDR 11: 16 bar | 63 mm | Typ E3 | 650 mm | 185 mm | 5,8 mm | 235 mm | 11,80 kg | ||||
4050753006
|
2) | 65 | Potable water SDR 11: 16 bar | 75 mm | Typ E3 | 660 mm | 180 mm | 6,8 mm | 305 mm | 16,70 kg | ||||
4050753007
|
2) | 65 | Potable water SDR 17: 10 bar | 75 mm | Typ E3 | 660 mm | 180 mm | 4,5 mm | 305 mm | 17,00 kg | ||||
4050903006
|
2) | 80 | Potable water SDR 11: 16 bar | 90 mm | Typ E3 | 670 mm | 180 mm | 8,2 mm | 315 mm | 20,00 kg | ||||
4050903007
|
2) | 80 | Potable water SDR 17: 10 bar | 90 mm | Typ E3 | 670 mm | 180 mm | 5,4 mm | 315 mm | 20,10 kg | ||||
4051103006
|
2) | 100 | Potable water SDR 11: 16 bar | 110 mm | Typ E3 | 710 mm | 185 mm | 10 mm | 345 mm | 27,50 kg | ||||
4051103007
|
2) | 100 | Potable water SDR 17: 10 bar | 110 mm | Typ E3 | 710 mm | 185 mm | 6,6 mm | 345 mm | 27,50 kg | ||||
4051253006
|
2) | 100 | Potable water SDR 11: 16 bar | 125 mm | Typ E3 | 755 mm | 180 mm | 11,4 mm | 345 mm | 33,00 kg | ||||
4051253007
|
2) | 100 | Potable water SDR 17: 10 bar | 125 mm | Typ E3 | 755 mm | 180 mm | 7,4 mm | 345 mm | 33,00 kg | ||||
4051403006
|
2) | 125 | Potable water SDR 11: 16 bar | 140 mm | Typ E3 | 755 mm | 180 mm | 12,7 mm | 120 mm | 31,40 kg | ||||
4051403007
|
2) | 125 | Potable water SDR 17: 10 bar | 140 mm | Typ E3 | 780 mm | 180 mm | 8,3 mm | 420 mm | 31,40 kg | ||||
4051603006
|
2) | 150 | Potable water SDR 11: 16 bar | 160 mm | Typ E3 | 790 mm | 180 mm | 14,6 mm | 460 mm | 52,50 kg | ||||
4051603007
|
2) | 150 | Potable water SDR 17: 10 bar | 160 mm | Typ E3 | 790 mm | 180 mm | 9,5 mm | 460 mm | 52,50 kg | ||||
4051803006
|
2) | 150 | Potable water SDR 11: 16 bar | 180 mm | Typ E3 | 810 mm | 175 mm | 16,4 mm | 435 mm | 57,40 kg | ||||
4051803007
|
2) | 150 | Potable water SDR 17: 10 bar | 180 mm | Typ E3 | 810 mm | 180 mm | 10,7 mm | 435 mm | 57,40 kg | ||||
4052002006
|
2) | 200 | Potable water SDR 11: 16 bar | 200 mm | Typ E2 | 895 mm | 190 mm | 18,2 mm | 565 mm | 79,00 kg | ||||
4052003007
|
2) | 200 | Potable water SDR 17: 10 bar | 200 | Typ E3 | 895 mm | 190 mm | 11,9 mm | 540 mm | 87,60 kg | ||||
4052253006
|
2) | 200 | Potable water SDR 11: 16 bar | 225 mm | Typ E3 | 895 mm | 190 mm | 20,5 mm | 540 mm | 89,60 kg | ||||
4052253007
|
2) | 200 | Potable water SDR 17: 10 bar | 225 mm | Typ E3 | 895 mm | 190 mm | 13,4 mm | 540 mm | 89,60 kg | ||||
8700000000
|
Surcharge for spindle bore | 0,00 kg |
-
Optional: The surcharge for the spindle bore (Ord. No. 8700000000) applies to gate valves up to DN 40.
Technical Documents
|
---|
declaration of conformity other fittings |
Operating instructions
|
---|
Operating and maintenance instructions - Hawle - E2, E3 gate valve |